Search

semiconductor

Semiconductor Vacuum Chamber Component - Case Study

Case study: titanium UHV chamber component for semiconductor equipment.

Case Facts

ApplicationUHV Chamber Component
MaterialGrade 5 Ti-6Al-4V
Processes5-axis-machining, surface-finishing
StandardsISO 9001
Tolerance±0.005 mm

Challenge

UHV component for etch chamber required: non-magnetic, minimal outgassing, Ra 0.2 µm finish.

Solution

Machined from Grade 5 forged billet on 5-axis. Electropolished to Ra 0.1 µm. Cleaned in Class 100 cleanroom.

Result

Outgassing < 10⁻⁹ Torr·L/s·cm². Non-magnetic verified. Zero particle contamination.